June 2004 Isis® Sonar User's Manual, Volume1 210
Figure 9-23: Pipe Tracking Setup dialog box
4. Using the - or + selector, select the Channel which is in use (1=port,
2=starboard, etc.).
5. Specify the Pipe Diameter. This is always displayed in inches (in), but
may be entered as meters (m), centimeters (cm) or millimeters (mm) by
entering the units immediately after the number (for example, 25cm).
6. Click APPLY to accept the diameter and apply the conversion.
7. Enter the Minimum Span Height in meters, the Minimum Span Length
in meters, and the Pipe Track Log Interval in seconds. In the Select
Items to Log panel, put check marks in those items you wish to log.
Because these values can vary widely according to surveyed data, there
are no default values for these parameters. The data for these
parameters will be written to an ASCII logging file having a file extension
of SPN.
8. Click BROWSE, and select a location and name for the logged data file.
(Isis automatically will provide the SPN extension.)